1804S Irrigation Control Cable

Description
Regency’s Irrigation Control Cable is manufactured for the purpose of power and control cable applications in accordance with the National Electric Code.
Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3 and B-8.
The insulation is color-coded Polyvinylchloride (PVC) Each insulated conductor is sheathed with a clear nylon jacket and are twisted and color-coded to facilitate pair identification.
The cable is then wrapped with an aluminum polyester tape.
Irrigation Control Cable is constructed in accordance with Underwriters Laboratories, Inc..
Application
Suitable for control circuits for operation and interconnection of protective and signaling devices. U.L. listed and labeled for
installation in duct, conduit and wireways. May be used in wet or dry locations, sunlight resistant, and suitable for direct burial.
Construction
Conductor:
- Soft drawn bare copper (ASTM Spec. B-3 and B-8).
- Four (4) conductors, Stranded
Size (AWG) | Number of Conductors | Conductor Stranding |
---|---|---|
18 | 4 | 7 |
Drain Wire: 20 AWG tinned copper laid between aluminum shield and PVC insulation
Insulation: Polyvinylchloride (PVC) with a nylon sheath. . Nom. Insulation Thickness .015”. Nylon Thickness .004”
Outer Jacket: Polyvinylchloride (PVC). Nom. Jacket Thickness .045”
Nominal O.D.: .335”
Shield: Aluminum/Polyester
Temperature: 90 C dry; 75 C wet
Voltage: 600 volts
Resistance: 6.92 OHMS per M at 68 Deg. F
Capacitance: 44.8 Pico Farads Nom
LBS./M’: 65
Color Coding: Per ICEA method 1; Pairs – black and white. One conductor in each pair is printed alphanumerically for easy identification